Home · Industries · Energy & Comm

Industry Route · Energy & Communication

Gateways that keep talking when the cabinet gets hot

In public-power and grid-tied setups, the board is not the switchgear — it is the data processing and communication layer: protocol gateways, telemetry nodes, cabinet controllers. These three boards carry the interfaces that work demands — dual LAN, PoE, wide DC input and −20/+60°C operation.

DUAL 2.5G LAN · PoE PSE · DC 9–36V · AMT · −20/+60°C

In The Cabinet

Four things a utility cabinet asks for

  • Communication density: the PDM-5110 quotes two Intel i226-V 2.5G ports plus a PoE PSE header — multiple segments and powered devices from one gateway.
  • Data processing at the node: Alder Lake-N and Twin Lake-N CPUs with onboard LPDDR5 up to 16GB on the PDM-5110 and AD742A run protocol conversion and telemetry close to the field.
  • Wide, sagging power: DC 9–36V on the TL500Z3AW rides substation and cabinet rails that sag under load; the PDM-5110 takes DC 12–24V.
  • Remote service: AMT on the TL500Z3AW management port plus a 0–255 s watchdog — out-of-band power control for cabinets nobody visits.
Utility corridor with power communication cabinets

Communication-Node Checklist

Match the cabinet, then the gateway

Typical requirements for the data processing and communication layer against the datasheet fields of the three recommended models.

Cabinet RequirementDatasheet FieldOn Board
Cabinet heat−20/+60°C operatingPDM-5110 · AD742A · TL500Z3AW
Segment links2× Intel i226-V 2.5GPDM-5110
Powered devicesPoE PSE headerPDM-5110 (AD742A: PoE optional)
Node computeAlder/Twin Lake-N, LPDDR5 16GBPDM-5110 · AD742A
Hard-wired railsDC 9–36VTL500Z3AW (PDM-5110: DC 12–24V; AD742A: DC 12V)
Remote managementAMT + watchdog 0–255 sTL500Z3AW

Questions

Energy & communication, answered

They handle the data processing and communication layer in public-power and grid-tied setups — protocol conversion, gateway routing and telemetry. They are not power-conversion hardware, and no utility certification is claimed on this page.

All three models quote −20 to +60°C operating temperature — cabinet air that runs warm in summer stays within the stated range without derating.

The PDM-5110 quotes a PoE PSE header and the AD742A lists PoE as optional — both per the published datasheet fields.

Get A Quote

Heat, sagging rails and no one to call — that is the cabinet.

Send the bus voltage, segment count and cabinet temperature — we’ll confirm the gateway board within 24–48 hours.

Request a Quote Contact Us